JSC "PromServis" started production of electromagnetic flow transducers EMIR-PRAMER-550 in 2006.
Appointment: transformation of volumetric flow rate and total volume of liquids in direct and reverse directions of stream in filled pipelines into output electric signal; broadcasting of the signal to external devices.
Application: industrial enterprises and municipal services, systems of hot and cold water supply, drinking water supply, objects of food industry.
Details
- Enclosure: modern design, increased protection against influence of environmental factors.
- No condensate: the case is completely protected from formation of condensate inside; it provides reliable operation in cold water supply systems.
- Indication of modes: quick and convenient diagnostics thanks to transparent cover and convenient interface.
- Reliable protection against noises: metal body provides high noise immunity and reliable results of measurements.
- Anti-vandal execution of protective case: carbon steel secure safety of magnetic system from unauthorized access.
- Warranty 8 years: long-term analysis of information regarding defects and failures of our devices, received from customers and service department, allowed to make a conclusion on their high performance, reliability and to set 8 years warranty period.
- Dynamic range up to 1/1000.
- Accuracy: up to ±1% in the whole flow range.
- Possibility to measure reverse flow.
- Self-diagnostic functions.
- 12V power supply unit is included into delivery pack.
Electromagnetic flow transducers EMIR- PRAMER- 550 are registered in State Register of Measuring Instruments, № 27104-08.
Electromagnetic flow transducers EMIR- PRAMER- 550 are protected by utility model patent № 48409.
DN: 15; 25; 32; 40; 50; 65; 80; 100; 150 mm.
Flow range depending on DN and dynamic range.
DN, mm | Flow-rate value, m3/h | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class А (1:100) | Class B (1:250) | Class C (1:500) | Class D, E (1:1000) | ||||||||||
Qmin | Qmax | Qmin | Qt1 | Qmax | Qmin | Qt2 | Qt1 | Qmax | Qmin | Qt2 | Qt1 | Qmax | |
15 | 0,06 | 6 | 0,024 | 0,06 | 6 | 0,012 | 0,024 | 0,06 | 6 | 0,006 | 0,024 | 0,06 | 6 |
25 | 0,16 | 16 | 0,064 | 0,16 | 16 | 0,032 | 0,064 | 0,16 | 16 | 0,010 | 0,064 | 0,16 | 16 |
32 | 0,25 | 25 | 0,100 | 0,25 | 25 | 0,050 | 0,100 | 0,25 | 25 | 0,025 | 0,100 | 0,25 | 25 |
40 | 0,4 | 40 | 0,160 | 0,40 | 40 | 0,080 | 0,160 | 0,40 | 40 | 0,040 | 0,160 | 0,40 | 40 |
50 | 0,6 | 60 | 0,240 | 0,60 | 60 | 0,120 | 0,240 | 0,60 | 60 | 0,060 | 0,240 | 0,60 | 60 |
65 | 1,0 | 100 | 0,400 | 1,00 | 100 | 0,200 | 0,400 | 1,00 | 100 | 0,100 | 0,400 | 1,00 | 100 |
80 | 1,6 | 160 | 0,640 | 1,60 | 160 | 0,320 | 0,640 | 1,60 | 160 | 0,160 | 0,640 | 1,60 | 160 |
100 | 2,5 | 250 | 1,000 | 2,50 | 250 | 0,500 | 1,000 | 2,50 | 250 | 0,250 | 1,000 | 2,50 | 250 |
150 | 6,0 | 600 | 2,400 | 6,00 | 600 | 1,200 | 2,400 | 6,00 | 600 | 0,600 | 2,400 | 6,00 | 600 |
Standard version of flow transducers is Class B (1:250).
Accuracy depending on dynamic range (Qmin/Qmax)), %:
Class A (1:100)
Qmax ... Qmin: ± 1;
Class B (1:250)
Qmax...Qt1: ± 1;
Qt1...Qmin: ± 2;
Class С (1:500)
Qmax...Qt1: ± 1;
Qt1...Qt2: ± 2;
Qt2...Qmin: ± 5;
Class D (1:1000)
Qmax...Qt1: ± 1;
Qt1...Qt2: ± 2;
Qt2...Qmin: ± 5;
Class Е (1:1000)
Qmax...Qmin: ± 1.
Parameters of controlled liquid:
- Temperature range: -1...+150 °С;
- Gage pressure: up to 1,6 MPa or up to 2,5 MPa;
- Ionic conductivity: 10-3...10 cm/m.
Technical characteristics:
- Power supply: 12 V DC;
- Power consumption: not more than 6 W;
- Resistance to mechanical impacts: group L1, GOST R 52931-2008;
- Protection degree: IP65;
- Average time between failures - no less than 75000 hours;
- Recovery time - max 4 hours;
- Average lifetime - 15 years;
- Recalibration interval - 4 years;
- Warranty period - 8 years.
Operating Condition:
- Ambient temperature: -10...+ 55°C;
- Humidity: up to 95% (without condensation);
- Atmospheric pressure: 84,0...106,7 kPa.